Symptom

The Brooktrout devices fail to initialise when starting the Zetafax server on a Windows 2003 or Windows XP (SP2) machine with 4GB or more of RAM. The server reports error messages similar to the one below:

BTBINIT    - (E) - Module 2 exists, but the firmware could not be downloaded to it.

Cause

The problem is occurring because the communication between the board and host is timing out in the environment described above.  This is happening because the Physical Address Extension (PAE) on the operating system is enabled by default.  The version of boston.sys currently used by the Zetafax Server does not support this setup.

Resolution

To resolve this issue, you have the following options:

  1. Remove RAM from the server so that it runs with less than 4GB.
  2. Disable PAE on the system.  Please read the following Microsoft technical note for further information on how to do this:

http://support.microsoft.com/kb/260544/en-us

Status

This has been identified by Equisys as a problem with the software versions given above.

Last updated: 8th January 2009 (GR/EB/SV/MW)

Equisys Logo, Document Management and Expense Management for Business Central
 

Replaced by script
Recent news

The sudden rush towards remote working practices in 2020 led many organizations to implement changes to upgrade their document capture processes on Microsoft Dynamics 365 Business Central or ...

Company credit cards are often seen as the most convenient way to incur travel & entertainment expenses, however it can be a very different story when it comes to the administration of these ...

North America
 
Equisys Inc
30000 Mill Creek Avenue
Suite 335
Alpharetta, GA 30022
USA
(770) 772 7201
Europe
 
Equisys Ltd
91 Southwark Bridge Road
London
SE1 0AX
United Kingdom
+44 (0)20 7203 4000
 

© Equisys Ltd
All rights reserved

© Equisys Ltd    All rights reserved    Contact    Privacy policy    Cookies