FIX: Faxes are displayed with the wrong time in the Zetafax Client after daylight savings time is applied

Print

ZTN1876

ID: ZTN1876

This Zetafax technical note applies to:

  • Zetafax Client v2012

Symptom

Files can be displayed with the wrong time in the Zetafax Client if daylight savings times has been applied. 

Cause

This problem is due to an incorrect calculation intended to handle daylight savings times when accessing a files modified date in Windows file systems.

Resolution

This issue has been resolved in the Zetafax 2012 Platform Feature Pack, available for download here. This update is available free of charge to existing Software Assuancre customers and can be accessed using the password provided in your Software Assurance newsletter. For more details on gaining access to this password email: support@equisys.com.

Status

This fault was corrected in the Zetafax 2012 Platform Feature Pack

Last updated: 26th November 2012 (JW/MW/AT)