PRB: Using /offpeak switch does not work with Zetafax SMTP Gateway

Print

ZTN1624

ID: ZTN1624

This Zetafax technical note applies to:

  • Zetafax configured with Zetafax SMTP Server

Symptom

According to ZTN1418 you can use a /offpeak switch in the subject line which should send the fax at the defined Off Peak time. However, in some instances it may not work, and the fax is sent immediately.

Cause

This is a known issue on some systems.

Resolution

As a workaround, you can define a Zetafax user's send time as required, so when the user sends a fax, it will be held until the allowed send time period.

Status

This has been identified by Equisys as a problem with the software versions given above.

Last updated: 14 August 2007 (AC/GC)

Keywords: offpeak switch