Equisys technical notes

Technical guidance, explanations and fixes for our products

PRB: Zetafax Web client Test.aspx reports "Not Attempted" for each of the tests.

Print

ZTN1346

ID: ZTN1346

This Zetafax technical note applies to:

  • Zetafax version 8.0.1 Web Client

Symptom

After you install the Zetafax Web Client you browse to http://localhost/zetafax to use it. Instead of the expected rich interface you get a flat HTML page with lots of unintelligible text. You then bring up the http://localhost/zetafax/test.aspx page to test the application, but all of the tests are 'Not Attempted'.

Cause

Internet Information Services (IIS) has been reinstalled and the ASP.Net script mappings have been lost.

Resolution

Use < windir> \Microsoft.NET\Framework\v1.1.4322\aspnet_regiis.exe with the -i switch  to install this version of ASP.NET and update scriptmaps at the IIS metabase root and for all scriptmaps below the root.

NOTE: Existing scriptmaps of lower version are upgraded to this version.

For more information please refer to Microsoft knowledge base article, 306005. "HOWTO: Repair IIS Mapping After You Remove and Reinstall IIS".

Status

This has been identified by Equisys as a problem when the conditions above occur.

Last updated: 11 February 2004 (GC/SV)