PRB: Error 'Invalid control character 0x06 in EPSON file' when rendering Adobe PDF files.
		
		
        
			Print
		
  
  
		ZTN1224
		
		
 
ID: ZTN1224
This Zetafax technical note applies to:
Symptom
When rendering Acrobat PDF files the following error may occur on the server log.
SYSMAN                - (I) -       QUEUEMAN SEND request SMTPMAIL:~MAIL000.CTL
QUEUEMAN      - (I) -       Queued new message SMTPMAIL:~MAIL000
QUEUEMAN      - (I) -       Converting message SMTPMAIL:~MAIL000
EPSTIFF                  - (I) -       Converting SMTPMAIL: ~MAIL000 (Addr 1), TXT -> G3F
EPSTIFF                  - (E) -      Invalid control character 0x06 in EPSON file
EPSTIFF                  - (E) -     Error converting page
EPSTIFF                  - (I) -       Conversion failed (error 0xF220)
QUEUEMAN      - (E) -     Error converting message (0xF220)
QUEUEMAN      - (E) -     Unable to find printable file for SMTPMAIL:~MAIL000
QUEUEMAN      - (I) -       Passing sent message status to mail gateway
QUEUEMAN      - (I) -       Completed message SMTPMAIL:~MAIL000 (1 failure)
STMAIL                      - (I) -       Passing message to mail system
Cause
The e-mail gateway can not render the document and fails to process the fax message when large Adobe Acrobat document (PDF) files are sent through the e-mail gateway, or more than one PDF file is attached to an e-mail message when sent to the Zetafax e-mail gateway.
Resolution
There are two possible solutions:
Pre-render the attachments by printing them to the Zetafax printer and saving the file from the client as a G3F file attachment.
Use the Document conversion engine to render PDF documents. This add-on supports over 250 file extensions and is a purchasable add-on to Zetafax.
Status
This has been identified by Equisys as a problem with the software versions given above.
Last updated: 12 December 2003 (JG/GC)