FIX: Zetafax Server intermittently misses incoming calls with some Brooktrout boards

Print

ZTN1717

ID: ZTN1717

This Zetafax technical note applies to:

  • Zetafax version 2008 (v12)

Symptom

When used with Brooktrout T1 E& M wink or analog DID boards, Zetafax intermittently misses incoming calls.

Cause

This is caused by the way in which the Zetafax device controller responds to timeouts when waiting for an incoming call.

Resolution

To resolve this problem, please perform the following steps: 

  1. Extract the files provided to a temporary location, e.g. c:\temp\
  2. Stop the Zetafax Server.
  3. Browse to < program files> \Zetafax Server\Server.
  4. Rename Devbtb.exe to Devbtb.exe.old.
  5. Copy the new file provided (Devbtb.exe) into your < program files> \Zetafax Server\SERVER\ folder.  Ensure that the file version is 12.0.675.
  6. Start the Zetafax Server.

Status

This behaviour was corrected as a hot-fix. Please contact Equisys support for download instructions.

Last updated: 16th December 2008 (HP/GC/MW)

Keywords: Zetafax Server

Equisys Logo, Document Management and Expense Management for Business Central
 

Replaced by script
Recent news

Understanding the profitability of projects is often a difficult and cumbersome process, especially if there is a lack of visibility around all the project costs. Getting that visibility of all ...

This article describes the new features and other improvements in the September 2021 update of the Zetadocs Expenses service. Zetadocs Expenses Release ...

North America
 
Equisys Inc
30000 Mill Creek Avenue
Suite 335
Alpharetta, GA 30022
USA
(770) 772 7201
Europe
 
Equisys Ltd
91 Southwark Bridge Road
London
SE1 0AX
United Kingdom
+44 (0)20 7203 4000
 

© Equisys Ltd
All rights reserved

© Equisys Ltd    All rights reserved    Contact    Privacy policy    Cookies