  • Brooktrout SDK 6.7.1

Symptom

Zetafax Server reports that a voice answered an outbound fax call when this is not the case (the line may be silent, or possibly busy in some circumstances). This results in a failed fax that is not retried.

Cause

This was caused by an incorrect detection of the status of the fax line. A ‘no loop current’ status was incorrectly interpreted as a voice answering the call.

Resolution

This fault was corrected in a hotfix, which is available by contacting Equisys Technical Support and quoting the technote number ZTN2097. This hotfix correctly reports the ‘no loop current’ status and fails the fax in the correct way, allowing the fax message to be retried.

Please note that this hotfix requires Brooktrout SDK version 6.7.1.

Status

This behaviour was corrected in the hotfix detailed above.

Last updated: 29th March 2016 (NT/JV) 

Keywords: Dialogic SR140 TR1034 TR114

Equisys Logo, Document Management and Expense Management for Business Central
 

Replaced by script
Recent news

The sudden rush towards remote working practices in 2020 led many organizations to implement changes to upgrade their document capture processes on Microsoft Dynamics 365 Business Central or ...

Company credit cards are often seen as the most convenient way to incur travel & entertainment expenses, however it can be a very different story when it comes to the administration of these ...

North America
 
Equisys Inc
30000 Mill Creek Avenue
Suite 335
Alpharetta, GA 30022
USA
(770) 772 7201
Europe
 
Equisys Ltd
91 Southwark Bridge Road
London
SE1 0AX
United Kingdom
+44 (0)20 7203 4000
 

© Equisys Ltd
All rights reserved

© Equisys Ltd    All rights reserved    Contact    Privacy policy    Cookies