ID: ZTN1397
This Zetafax technical note applies to:
Some older Brooktrout TR1034 boards are not correctly identified by the latest Brooktrout API and the Zetafax Server. These boards need to be added manually using the Brooktrout Configuration Tool in off-line mode. This document describes how to do this.
Note: this technical note applies to systems where an older board is being configured with Zetafax for the first time. If you have Zetafax version 8 or 9 system already configured with a TR1034 card and wish to use Zetafax version 9.1, you must refer to this technical note ZTN1394-HOWTO Upgrade Brooktrout TR1034 Installations from Zetafax version 8 or 9 Pre SP1.
When trying to configure the Brooktrout board using the Brooktrout Device Configuration tool or Zetafax configuration snap in, you receive one of the following error messages.

"The board has no working channels. Check that the firmware been applied correctly"

"BfvLineReset for module 0x2 failed (Misc error: Packet recive error.: status 8000020)."




ZTN1400-INFO Brooktrout TR1034 and TruFax BRI technical note references for Zetafax.
ZTN1399-INFO Brooktrout Initialisation Error Messages.
ZTN1395-HOWTO Install and configure Brooktrout TR1034 and TruFax BRI intelligent fax boards.
ZTN1394-HOWTO Upgrade Brooktrout TR1034 Installations from Zetafax version 8 or 9 Pre SP1.
Last reviewed: 11 November 2005 (GC/EB)
Date Published: 8 September 2004 (GR/SV)