Equisys Technical Notes

Technical guidance, explanations and fixes for our products

 

TechNotes_Parallax

FIX: Zetadocs stops processing documents in the batch split folder

Print

ZTN4492

This Zetadocs technical note applies to:

  • Version 8 of Zetadocs Server or later

Symptom

Documents in the batch split folder are not being processed by Zetadocs. Although the Zetadocs Document Converter service continues to run, it requires a manual restart in order to begin processing documents again.

Upon looking in the ZdDocumentConverter log there may be an error message stating:
            “BatchScanFolders_Error(): An error has occurred: Too many changes at once in directory”

Cause

This is caused by too many events occurring in the batch split folder in a short amount of time, possible causes for this include; a large file being streamed/scanned to the folder, or a large number of files being added to the folder at once.

Resolution

This fault was corrected in a hotfix, which is available by contacting Equisys Technical Support and quoting the technote number ZTN4492.

Status

This behaviour was corrected in the ZTN4492 hotfix detailed above.

Last updated: 26th April 2017 (JL/JV) 

Keywords: Zetadocs NAV Server, Batch Split Folder, Document Converter

Name:
Email:
Subject:
Message:
x
EquisysLogo

Recent news

Now we’re past the May 25 th deadline, the dust is starting to settle on GDPR. If, like most of us, you received a flurry of “please opt in” emails in the run up to that “fateful Friday”, you’ll ...

This article describes the new features and other improvements in the June 2018 release of the Zetadocs Expenses service. Zetadocs Expenses ...